15
ATTACHING THE MCR 5000 IN THE PLACE OF INSTALLATION
The MCR 5000 device is installed including the pre-installed bracket at the place of
installation by using 6 x M6 screws and must be held in place by an additional person
during installation.
.
Attention:
a thread depth of at least 12 and at most 15 mm inside the MCR 5000 device must be
observed. Use all six screwing points.
E
XAMPLE FOR INSTALLING THE MCR 5000 TO A WOODEN WALL FROM
18 MM PLYWOOD
Required installation materials (not included in the scope of delivery):
6 units of M6 x 35 Allen screw acc. to DIN 912
6 units of M6 washer for wooden constructions acc. to
DIN 440R
Note:
The screw length for each individual place of installation is determined in the following
way:
Wall thickness (18mm) + washer thickness (2 mm) + required penetration
depth (12 - 15mm) = screw length = 35 mm.
The 6 screws together with their washers will directly beneath the screw head be put
through holes drilled in the wall, screwed into the blind-rivet nuts in the MCR 5000 device,
and subsequently tightened with a torque of 5 Nm.